Class D ampli ers can represent signals with three di erent output levels, +Vcc, 0, -Vcc, with no distortion. Exploiting this in order to achieve a better performance with no switching frequency increase, an extension to the classic Pulse Width Modulation two level A/D conversion is proposed. Coding is achieved by extending output waveforms of a Trellis based Sigma Delta Modulation to three levels. Simulation results have shown that, using the same symbol rate, a three level pattern achieved from 3:7 to 8:2 dB of SINAD improvement and a power consumption up to 5 times smaller.
https://www.aes.org/e-lib/browse.cfm?elib=13500
Click to purchase paper as a non-member or login as an AES member. If your company or school subscribes to the E-Library then switch to the institutional version. If you are not an AES member and would like to subscribe to the E-Library then Join the AES!
This paper costs $33 for non-members and is free for AES members and E-Library subscribers.